RETROTEC Blower Door 5220X (RIPCI)

20.650,00 + VAT

Availability: 11-15 days

Ref: EU5220X-F

Do you have any doubts?

Contact our technical-sales department

Apliter Renting

Finance your purchase from 360 €/month

Description

RETROTEC Blower Door 5220X (RIPCI)

Equipment valid for RIPCI test according to UNE-EN 15004-1

RETROTEC EU5220X-F equipment is one of the main equipment for performing Door Fan Test, of mandatory compliance, according to the Regulation of Fire Protection Installations (RIPCI), published in Royal Decree 513/2017 on May 22. The RIPCI requires the realization of a Door Fan Test according to UNE-EN 15004-1 standard to determine the minimum dwell time of the extinguishing agent in extinguishing systems using gaseous agents.

The RETROTEC 5220X-F is one of the most commonly used Blower Door testers for leak testing in fire protection installations using gaseous extinguishing systems.
This complete Blower Door Test System is designed to easily perform leak tests in the vast majority of volumes. The calibrated fan model 5000 has a power of 0.55 kW and achieves a flow rate of 9,684 m3/h. Thanks to the two fans of the RETROTEC EU5220X-F unit, we obtain a power of 1.10 kW and reach a flow rate of 19,368 m3/h, making it ideal to comply with the requirements of the RIPCI and UNE-EN 15004-1 in your projects.

Door Fan Test with Leakage Neutralization in False Ceiling

RETROTEC Blower Door 5220X-F equipment is capable of performing the Blower Door test for determination of the Lower Leakage Fraction (F) according to the False Ceiling Leakage Neutralization Method. This method is detailed in NFPA 2001:2015, international reference standard for gaseous agent fire extinguishing systems.

Thanks to the Leakage Split Kit included in the RETROTEC Blower Door 5210X-F, you have everything you need to apply this methodology to determine the Lower Leakage Fraction (F). Achieve better and more accurate results in your tests: By justifying a Lower Leakage Fraction you will achieve longer residence times in your facilities!

RETROTEC 5220X-F Blower Door System with pressure gauge DM32X

The software supplied with the DM32X smart meter automatically performs data logging and allows remote control of the meter from a laptop PC.

The recommended calibration interval for the DM32X pressure gauge is 5 years, giving you the peace of mind and the savings of avoiding costly annual calibrations, which are now a thing of the past.

Maximum mounting adaptability

As a special feature, the RETROTEC 5220X-F Blower Door system includes a modular rigid door and a larger aluminum-framed fabric door.
The rigid door provides maximum installation speed, robustness and durability. Use these doors for the most professional inspections. You will be able to perform the Blower Door test in less time and with maximum robustness of the assembly.
The larger, easy-to-install fabric door allows you to perform the Blower Door test on large doors without the need for any adaptations.

RETROTEC, pioneer in Door Fan testing

RETROTEC 5220X-F equipment allows testing the minimum dwell time according to the reference standards UNE-EN 15004, ISO 14520 or NFPA 2001. RETROTEC is a pioneer and leading manufacturer and researcher of leak testing in fire protection installations, actively participating in the development of NFPA standards for fire protection since 1984.

  Rechargeable Li-Ion batteries
 All units and measurement standards
 Carrying case for accessories
Quick assembly and disassembly
Super-strong fan structure
 Ergonomic design
 Informative display
 Less heat - More power
 11 fan configurations. Greater flexibility
 Precise fan calibration

REF.EU5220X-F

Blower door RETROTEC - Pressure gauge tutorial DM32X

RETROTEC Blower door - Quick Installation Guide

Features

Fans
Fan model5000
Number of fans2
Maximum flow rate (in free air)2 x 10.874 = 21.748 m3/h (at 60 Hz)
Maximum flow rate (at 50Pa)2 x 9,684 = 19,368 m3/h (at 60 Hz)
Minimum flow rate (at 10Pa)14 m3/h (with optional diaphragm range B29)
Manometer / Gauge
Pressure gauge/gauge modelDM32 WiFi
Number of pressure gauges2
Door / Panel
Type2 Doors: Modular rigid panel + 50″ fabric panel with aluminum frame.
Width (min/max)81 cm / 124 cm (Modular rigid panel)
High (min/max)194 cm - 221 cm (Modular rigid panel)

Box contents

Digital pressure gauge pack DM32X (1 pc):

  • Pressure gauge DM32X
  • USB-C charging cable
  • Cat5 Ethernet cable
  • Holster
  • Magnetic clip DM32X
  • Calibration verification report

SmartCloth 50″ fabric door pack (1 pc):

  • 50″ aluminum frame
  • Standard SmartCloth fabric tarpaulin for 1 fan 5000
  • Carrying case

Modular rigid door pack for 1 fan 5000/6000 series (1 pc):

  • 5000/6000 series fan panel
  • Large filler sheet for fan panel
  • Small filler sheet for fan panel
  • Large X panel
  • XY Panel
  • Carrying case for panel
  • Fan retaining strap

Pack fan series 5000 (2 pcs):

  • 5000 series fan
  • 10 Diaphragms (1 A-ring, 1 tray for B8 and 8 B8 plugs)
  • Power cable
  • Front or rear fan shroud
  • Calibration verification report
  • Rigid carrying case

Leakage Split Kit ***(1 pc):

  • Flexible Duct for testing Door Ventilator by Leakage Neutralization Method in false ceiling.
  • Panel for testing Door ventilator in protected volumes below the raised access floor
  • Plate for field calibration verification
  • Sealing film for false ceiling with rectangular panel
  • Carrying case for flexible duct, with carrying strap and triangular upright
    ***Compatible with fans 5000 and 6000

Accessories:

  • Large fabric tarpaulin for 2 fans (1 pc.)
  • Carrying case for accessories (2 pcs)
  • 5000 series ventilator umbilical cable (2 pcs.)
  • Pressure hose kit for blower door (2 pcs)

Related products