Fan Door Test C.3 Course - Fixed Fire Protection Systems: Category 3

Consult price

Availability: On request

Ref: AP001292_3
Request a quote

Do you have any doubts?

Contact our technical-sales department

Description

Fan Door Test C.3 Course - Fixed Fire Protection Systems: Category 3

Category 3 course given by Retrotec to perform the Blower Door Test, a test specifically required for compliance with the Fire Protection Installations Regulation (RIPCI), according to Royal Decree 513/2017 of May 22 published in the Official State Gazette (BOE) of June 12, 2017. The syllabus delves into the Door Fan Test according to UNE-EN 15004-1, ISO 14520 and NFPA 2001 standards and their particularities in enclosures with complex envelopes. Technicians will learn advanced analysis techniques: Infiltration measurement through pressure neutralization tests using two Door Ventilator equipment simultaneously, sectorization techniques using plastic membranes, among others.

Competencies

This course provides certified training to perform the Blower Door Test to determine the dwell time according to UNE-EN 15004, ISO 14520 or NFPA 2001 standards in compliance with the Fire Protection Installations Regulations.

Retrotec Blower Door Test Training

Retrotec is a pioneer in the design and manufacture of equipment for Blower Door Testing. It is internationally recognized for the quality of its products and its contribution to the development of the sector: Since 1980 the company has actively participated in the elaboration of standards for Blower Door Testing in the main standardization committees: ISO, NFPA and USACE.

Program

  • Advantages of measuring low infiltration values
  • Flexible duct testing
  • Test with plastic membranes on roofs
  • Tests on the technical floor
  • Multi-fan testing
  • Extended download
  • Complex volumes

 

Practices

Using Retrotec's FanTestic Integrity software, the software allows performing the analyses required by the current standards UNE-EN 15004, ISO 14520 and NFPA 2001.

Speakers. Infiltrometry Technical Instructors.

Retrotec's Blower Door Testing courses are developed and taught by personally appointed infiltrometry technical instructors. They have all the accreditations, many years of experience and the know-how of the world's leading producer of Blower Door equipment to perform the Blower Door Test.

Target audience
Technicians responsible for performing the Blower Door Test for compliance with the Fire Protection Installations Regulation and responsible for the design of fixed fire fighting systems who want to deepen, expand their knowledge and have the highest certification in the performance of Blower Door Tests in Fire Protection installations.

Duration

8 hours

Prerequisites

To attend the Door Fan Testing Course applied to Fixed Fire Systems: Category 3, you must have attended the Door Fan Testing Course applied to Fixed Fire Systems: Category 2.

Language

Spanish

Obtaining the title

In order to obtain the certificate, participants must pass a multiple-choice test at the end of the course.