FLIR A615 Thermal Imaging Camera

Thermal imaging camera available with a 7º, 15º, 25º, 45º or 80º lens.

Consult price

Availability: 11-15 days

Ref: FLIR-A615-P
Request a quote

Do you have any doubts?

Contact our technical-sales department

Are you a distributor/integrator?

Contact our corporate department.

Apliter Renting

Finance your purchase from 315 €/month

Description

FLIR A615 Thermal Camera

Automated 24/7 monitoring applications

FLIR A615 Infrared Camera for 24/7 Monitoring of Critical Installations

The FLIR A615 thermal imaging camera is easily controllable, affordable and compact for critical facility monitoring, industrial process control and early fire detection. The FLIR A615 thermal camera can be fully controlled with a PC or easily integrated with third-party machine vision software such as National Instruments, Cognex, Matrox, MVtec and Stemmer Imaging. The FLIR A615 thermal camera is available with a 7°, 15°, 25°, 45° or 80° lens.

Features FLIR A615 thermal imaging camera

Outstanding image quality

The FLIR A615 features a 640×480 (307,200) pixel detector that can detect temperature differences as small as 0.05°C.

16-bit linear temperature output

Capture non-contact temperature measurements with third-party software thanks to the 16-bit linear temperature output.

High-speed streaming

Transmit full-frame radiometric images at 50fps or reach up to 200fps through windowing.

Ref. 55001-0101, 55001-0102, 55001-0103, 55001-0104, 55001-0105

FLIR A615 - Introduction to Thermal Imaging Camera

FLIR A615 - Thermal camera for industrial automation and safety

FLIR A615 - Training with Cognex VisionPro

FLIR A615 - With Pan & Tilt System

Technical Data

Imaging and optical data ( For 25º lens)

IR resolution
640 × 480 pixels
Thermal sensitivity/NETD
< 0.05°C @ +30°C (+86°F) / 50 mK
Field of view (FOV)
25° × 19° (31° diagonal)
Minimum focus distance
0.25 m (0.82 ft.)
Focal length
24.6 mm (0.97 in.)
Spatial resolution (IFOV)
0.68 mrad
Lens identification
Automatic
F-number
1.0
Image frequency
50 Hz (100/200 Hz with windowing)
Focus
Automatic or manual (built in motor)

Detector data

Detector type
Focal plane array (FPA), uncooled microbolometer
Spectral range
7.5-14 µm
Pitch detector
17 µm
Detector time constant
Typical 8 ms

Measurement

Object temperature range
  • -40°C to +150°C (-40°F to +302°F)
  • 100 to +650°C (+212 to +1202°F)
  • 300 to +2000°C (+572 to +3632°F)
Accuracy
±2°C (±3.6°F) or ±2% of reading

Measurement analysis

Atmospheric transmission correction
Automatic, based on inputs for distance, atmospheric temperature and relative humidity
Optics transmission correction
Automatic, based on signals from internal sensors
Emissivity correction
Variable from 0.01 to 1.0
Reflected apparent temperature correction
Automatic, based on input of reflected temperature
External optics/windows correction
Automatic, based on input of optics/window transmission and temperature
Measurement corrections
Global object parameters

USB

USB
  • Control and image
USB, standard
USB 2 HS
USB, connector type
  • USB Mini-B
USB, communication
TCP/IP socket-based FLIR proprietary
USB, image streaming
16-bit 640 × 480 pixels @ 25 Hz
  • Signal linear
  • Temperature linear
  • Radiometric
USB, protocols
TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnP

Ethernet

Ethernet
Control and image
Ethernet, type
Gigabit Ethernet
Ethernet, standard
IEEE 802.3
Ethernet, connector type
RJ-45
Ethernet, communication
TCP/IP socket-based FLIR proprietary and GenICam protocol
Ethernet, image streaming
16-bit 640 × 480 pixels @ 50 Hz
16-bit 640 × 240 pixels @ 100 Hz
16-bit 640 × 120 pixels @ 200 Hz
  • Signal linear
  • Temperature linear
  • Radiometric
GigE Vision and GenICam compatible
Ethernet, protocols
TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnP

Digital input/output

Digital input, purpose
Image tag (start, stop, general), Image flow control, (stream on/off), Input ext. device (programmatically read)
Digital input
2 opto-isolated, 0-1.5 V = low, 3-25 V = high
Digital output, purpose
Output to ext. device (programmatically set)
Digital output
2 opto-isolated, ON = supply (max. 100 mA), OFF = open
Digital I/O, isolation voltage
500 VRMS
Digital I/O, supply voltage
6-24 VDC, max. 200 mA
Digital I/O, connector type
6-pole jackable screw terminal

Power system

External power operation
12/24 VDC, 24 W absolute max.
External power, connector type
2-pole jackable screw terminal
Voltage
Allowed range 10-30 VDC

Environmental data

Operating temperature range
-15°C to +50°C (+5°F to +122°F)
Storage temperature range
-40°C to +70°C (-40°F to +158°F)
Humidity (operating and storage)
IEC 60068-2-30/24 h 95% relative humidity +25°C to +40°C (+77°F to +104°F)
EMC
  • EN 61000-6-2:2001 (Immunity)
  • EN 61000-6-3:2001 (Emission)
  • FCC 47 CFR Part 15 Class B (Emission)
Encapsulation
IP 30 (IEC 60529)
Shock
25 g (IEC 60068-2-27)
Vibration
2 g (IEC 60068-2-6)

Physical data

Weight
0.90 kg (1.98 lb.)
Camera size (L × W × H)
216× 73 × 75 mm (8.5 × 2.9 × 3.0 in.)
Camera size, excl. lens (L × W × H)
203× 73 × 75 mm (8.0 × 2.9 × 3.0 in.)
Tripod mounting
UNC ¼"-20 (on three sides)
Base mounting
2 × M4 thread mounting holes (on three sides)
Housing material
Aluminum
Comments to physical data
Outline dimensional drawings and STEP files can be found at http://support.flir.com

Shipping information

Packaging, type
Cardboard box
List of contents
  • Infrared camera with lens
  • Ethernet cable
  • Mains cable
  • Power cable, pig-tailed
  • Power supply
  • Printed
  • Printed documentation
  • USB cable
  • Utility CD-ROM
Packaging, weight
Packaging, size
360 × 180 × 550 mm (14.2 × 7.1 × 21.7 in.)
EAN-13
7332558003251
UPC-12
845188002732
Country of origin
Sweden

Box contents

  • FLIR A615 thermal imaging camera with 7º, 15º, 25º, 45º or 80º lens
  • Ethernet cable
  • Mains cable
  • Power cable, pigtail
  • Power supply
  • USB cable
  • Printed documentation

Related products