The FLIR A500-EST fixed thermal camera is a non-contact temperature measurement tool that acts as the first line of detection for potential fever cases. The FLIR-EST thermal imaging solution quickly identifies individuals with elevated skin temperature. With a 464×348 pixel sensor and FLIR Screen-EST mode, the FLIR A500-EST can be used as a stand-alone detection station or networked with other units.

The FLIR A500-EST thermal imaging camera can be easily integrated with third-party equipment thanks to its support for industry standards Modbus TCP, MQTT, RESTful API for file transfer and RTSP for video. The camera can be connected to most video management systems and is compatible with FLIR Screen-EST desktop software.

 

Plug&Play camera

Easily integrates into web services with RESTful API via XML or JSON; offers standard connection via EtherNet or Wi-Fi. Easy to configure and use.

Accuracy and real-time detection

Optimum measurement accuracy with automatic environmental drift compensation; optionally supports external blackbody compensation.

Security and privacy

The FLIR-EST in-camera mode does not store images or personal information and allows respecting the social distance in the detection zones.

Ref. 90601-0101, 90602-0101

FLIR Screen-EST™ - Introduction

Technical Data

Imaging and optical data

(for 24º lens)
Infrared resolution
464 x 348 pixels
Thermal sensitivity (NETD)
<40 mK, 24° @ +30°C (+86°F)
Field of view (FOV)
24° × 18°
Minimum focus distance
0.15 m (0.49 ft)
Focal length
17 mm (0.67 in)
Spatial resolution (IFOV)
0.90 mrad/pixel
Lens identification
Automatic
f-number
1.3
Image frequency
30 Hz
Focus
  • One-shot contrast
  • Motorized
  • Manual

Detector data

Focal plane array/spectral range
Uncooled microbolometer/7.5-14 µm
Pitch detector
17 µm

Measurement

Camera temperature range
15 to 45°C (59 to 113°F)
Accuracy ±0.3°C (±0.5°F) when used in Screening mode
The camera will provide contrast from -20 to 120 °C (-4 to 248°F), but no temperature information will be provided

Measurement analysis

Automatic hot/cold detection
Max./min. temperature value and position shown within Box
Schedule response
sftp (image), SMTP (image and/or measurement data/result)
Measurement presets
Yes
Atmospheric transmission correction
Based on inputs of distance, atmospheric temperature, and relative humidity
Lens transmission correction
Automatic, based on signals from internal sensors
Emissivity correction
Variable from 0.01 to 1.0
Reflected apparent temperature correction
Based on input of reflected temperature
External optics/windows correction
Based on input of optics/window transmission and temperature
Measurement corrections
  • Global object parameters
  • Local parameters per analyze function
  • External Black-body correction
Measurement frequency
Up to 10 Hz
Measurement result read-out
  • Ethernet/IP (pull)
  • Modbus TCP master (push)
  • Modbus TCP slave (pull)
  • MQTT (push)
  • Query over REST API (pull)
    Measurements and still image (radiometric JPEG, visual 640 × 480, visual 1280 × 960), read access only.
  • Web interface

Alarm

Alarm functions
  • On any selected measurement function
  • Digital in
  • Internal camera temperature
Alarm output
  • Digital out
  • E-mail (SMTP) (push)
  • EtherNet/IP (pull)
  • File transfer (FTP) (push)
  • Modbus TCP master write (push)
  • Modbus TCP slave (pull)
  • MQTT (push)
  • Query over RESTful API (pull)
  • Store image or video

Configuration of camera

Web interface
Yes

Recording of still images/video

Image storage
  • Format: FLIR radiometric JPEG
  • Number of images: 100
  • Storage as function of:
    • Alarm
    • Scheduling
    • User interaction (web camera)
Video storage
  • Format: H.264
  • Number of videos: 10
  • Storage as function of alarm; 5 sec. before alarm and 5 sec. after alarm.

Video/Radiometric streaming RTSP

Protocol
RTSP
Unicast
Yes
Multicast
Yes
Multiple image streams
Yes
Video streaming
Image quality
Bit rate set through Camera web
Video streaming, Image source 0:
Resolution (source 0)
640 × 480 pixels
Contrast enhancement
FSX / Histogram equalization (IR only)
Overlay (source 0)
With / Without
Image source (source 0)
Visual / IR / MSX
Pixel format (source 0)
YUV411
Encoding (source 0)
H.264 / MPEG4 / MJPEG
Video streaming, Image source 1:
Resolution (source 1)
1280 × 960 pixels
Overlay (source 1)
No
Image source (source 1)
Visual
Pixel format (source 1)
YUV411
Encoding (source 1)
H.264 / MPEG4 / MJPEG
Radiometric streaming
Resolution (radiometric)
640 × 480 pixels
Source
IR
Pixel format (radiometric)
MONO 16
Encoding (radiometric)
  • Compressed JPEG-LS
  • FLIR Radiometric

Ethernet

Interface
  • Wired
  • Wi-Fi
Connector type
  • M12 8-pin X-coded, Female
  • RP-SMA, Female
Ethernet, purpose
Control, result, image, and power
Ethernet, type
1000 Mbps
Ethernet, standard
IEEE 802.3
Ethernet, communication
TCP/IP socket-based FLIR proprietary
Ethernet, power
Power over Ethernet, PoE IEEE 802.3af class 3
Ethernet, protocols
  • EtherNet/IP
  • IEEE 1588
  • Modbus TCP Master
  • Modbus TCP Slave
  • MQTT
  • SNMP
  • TCP, UDP, SNTP, RTSP, RTP, HTTP, HTTPS, ICMP, IGMP, sftp (server), FTP (client), SMTP, DHCP, MDNS (Bonjour), uPnP

Digital Input/ output

Connector type
M12 12-pin A-coded, Male (shared with external power)
Digital input
2x opto-isolated
Vin(low)= 0-1.5 V, Vin(high)= 3-25 V
Digital input, purpose
  • NUC
  • NUC disable
  • Alarm
  • Update screening reference sample
Digital output
  • 3x opto-isolated, 0-48 V DC, max. 350 mA (derated to 200 mA at 60C)
  • Solid state opto relay
  • 1x dedicated as Fault output (NC)
Digital output, purpose
  • As function of alarm, output to external device, for example when the screening alarm is triggered.
  • Fault (NC)
Digital I/O, isolation voltage
500 VRMS

Power system

Connector type
M12 12-pin A-coded, Male (shared with Digital I/O)
Power consumption
  • 7.5 W at 24 V DC typical
  • 7.8 W at 48 V DC typical
  • 8.1 W at 48 V PoE typical
External power operation
24/48 V DC 8 W max
External voltage
Allowed range 18-56 V DC

Wi-Fi (Option)

Connector type
RP-SMA, Female
Standard
IEEE802.11a/b/g/n
Antenna
Dipole antenna 2.4/5 GHz (gain: maximum 2 dBi)
Connection type
Peer to peer (ad hoc) or infrastructure (network)

Environmental data

Operating temperature range
-20 to 50°C (-4 to 122°F)
Cooling plate is needed in temperatures above 40°C (104°F).
Maximum camera case temperature: 65°C (149°F)
Storage temperature range
IEC 68-2-1 and IEC 68-2-2-2, -40 to 70°C (-40 to 158°F) for 16 hours
Humidity (operating and storage)
IEC 60068-2-30/24 hours, 95% relative humidity, 25-40°C (77-104°F)/2 cycles
EMC
  • ETSI EN 301 489-1 (radio)
  • ETSI EN 301 489-17 (radio)
  • EN 61000-4-8 (magnetic field)
  • FCC 47 CFR Part 15 Class B (emission US)
  • ISO 13766-1 (EMC - Earth-moving and building construction machinery)
  • EN ISO 14982 (EMC - Agricultural and forestry machinery)
Radio spectrum
  • FCC 47 CFR Part 15 Class C (2.4 GHz band US)
  • FCC 47 CFR Part 15 Class E (5 GHz band US)
  • RSS-247 (2.4 GHz and 5 GHz band Canada)
  • ETSI EN 300 328 V2.1.1 (2.4 GHz band EU)
  • ETSI EN 301 893 V2.1.1 (5 GHz band EU)
Encapsulation
IEC 60529, IP 54, IP66 with accessory
Shock
IEC 60068-2-27, 25 g
Vibration
  • IEC 60068-2-6, 0.15 mm at 10-58 Hz and 2 g at 58-500 Hz, sinusoidal
  • IEC 61373 Cat 1 (Railway)
Safety
IEC 62368-1 (IT equipment audio-visual products)
Corrosion
  • ISO 12944 C4 G or H
  • EN60068-2-11

Physical data

Weight
0.82 kg (1.8 lb)
Size (L × W × H)
139 × 77 × 77 mm (5.47 × 3.03 × 3.03 in)
Base mount
4× M4 on 4 sides
Tripod mounting
UNC ¼″-20 on 2 sides
Housing material
Aluminium
Color
Black

Warranty and service

Warranty
http://www.flir.com/warranty/

Shipping information

Packaging, type
Cardboard box
Packaging, contents
  • Infrared camera
  • Lens
  • Ethernet cable M12 to RJ45F (0.3 m), P/N T911869ACC
  • Wi-Fi option including antenna
  • Printed documentation including the username and password for log in to the web interface of the camera
Packaging, weight
1.14 kg (2.51 lb)
Packaging, size
207 × 142 × 129 mm (8.15 × 5.59 × 5.08 in)
EAN-13
7332558027028
UPC-12
845188023096
Country of origin
Sweden

Box contents

  • FLIR A500-EST thermal imaging camera
  • Selected lens
  • M12 to RJ45F Ethernet cable (0.3m)
  • WiFi option with antenna
  • Printed documentation