FLIR GIS-320 OGI Gas detection thermal imaging camera

This product is discontinued.
This is the model that replaces it:

Description

FLIR GIS-320 OGI thermal imager

for gas detection

 

Workswell GIS-320 thermal camera for mobile platforms, including unmanned aerial systems and ground vehicles (UAS/UGV).
This thermal imaging camera for gas detection is the perfect solution to safely detect methane as well as more than 200 hydrocarbons and VOC emissions resulting from oil and gas production, transportation and use.

The Workswell GIS-320 IR camera is built around a cooled infrared detector that provides industry-leading gas detection capability and the sensitivity needed to meet the U.S. EPA OOOOa methane standard.

The Workswell GIS-320 thermal imaging camera can detect leaks in hard-to-reach areas or inspect wellheads spread over large areas in a single pass, making this OGI system a valuable tool for any leak detection and repair (LDAR) program.

Gas detection from a safe distance

  • Reduce health and safety risks by adding the Workswell GIS-320 thermal camera to LDAR programs.
  • Discover hidden gas leaks with 320 × 240 pixel resolution
  • Resolución IR y sensibilidad a la temperatura de <15 mK
  • Record both visible and thermal video with up to 10x optical zoom (visual camera)
  • Visualize more than 200 gases, including methane, benzene and ethylene
  • High sensitivity cooled FLIR detector with a spectral range between 3.2-3.4 µm

Seamless integration with UAS/UGV platforms

  • Remote inspection of wellheads, pipelines, tank batteries, etc.
  • Linking to popular RC control systems with industry-standard connections
  • Easy integration through the use of inputs/outputs, including HDMI, SBUS, CAN and GPS-MavLINK
  • Compatible with Gremsy T7 threaded brackets or ¼-20 threaded brackets

Complies with standards

  • See small leaks with FLIR's patented noise reduction filter and high sensitivity mode (HSM)
  • Verify leak location by viewing visible and thermal spectrum images simultaneously
  • Set up and start inspecting faster with FLIR's standard OGI system interface

Ref. GIS-320-14, GIS-320-24

FLIR GIS-320 OGI Thermal Imager - Presentation

FLIR GIS-320 OGI Thermal Camera - Gas Detection Mode

FLIR GIS-320 OGI Thermal Camera - Flight Test

FLIR GIS-320 OGI Thermal Camera - Gimbal Mount

Technical data

Imaging and optical data - For 24º lens

IR resolution
320 × 240 pixels
Thermal sensitivity/NETD
<15 mK @ +30°C (+86°F)
Field of view (FOV)
24° × 18°
Minimum focus distance
0.3 m (1.0 ft)
Focal length
23 mm (0.9 in)
F-number
1.5
Focus
Automatic motorized focus
Zoom
1-8× continuous, digital zoom
Digital image enhancement
Noise reduction filter, High Sensitivity Mode (HSM)

Detector data

Detector type
Focal plane array (FPA), cooled InSb
Spectral range
3.2 - 3.4 µm
Sensor cooling
Stirling Microcooler (FLIR MC-3)
MTBF
Two years or 15,000 hours (whichever is greatest), for a camera running 24/7 @ +20°C (+68°F)
Detects following gases
Benzene, ethanol, ethyl-benzene, heptane, hexane, isoprene, methanol, methyl ethyl ketone, MIBK, octane, pentane, 1-pentene, toluene, m-xylene, ethane, butane, methane, propane, ethylene, propylene

Electronics and data rate

Full frame rate
60 Hz

Image presentation

Automatic image adjustment
Continuous/manual; linear or histogram based
Manual image adjustment
Level/span

Image presentation modes

Image modes
IR image, High Sensitivity Mode (HSM)

Measurement

Temperature range
-20°C to +350°C (-4°F to +662°F)

Video streaming

Non-radiometric IR video streaming
Image: 16-bit 320 × 240 pixels at 30 Hz
Video: 640 × 480 pixels at 30 Hz

Data communication interfaces

Interfaces
  • HDMI
  • Ethernet
  • 10-pin digital port

USB

USB
Control and image
USB, standard
2.0 High Speed
USB, connector type
USB standard
USB, video streaming
640 × 480 pixels at 30 Hz (using USB video class)
USB, image streaming
16-bit 320 × 240 at 30 Hz (using USB video class)

Ethernet

Ethernet
Future connectivity

Digital input/output

Digital output
10-pin digital port:
S.BUS, CAN bus (compatible with DJI M600 and A3 controllers), MavLink External GPS connectivity and external trigger

Power system

DC operation
9 - 36 VDC, Coaxial 2 × 6.4 mm, outer shell - GND
Power
18 W
Start-up time
Typically 7 min. @ 25°C (77°F)

Environmental data

Operating temperature range
5°F to 122°F (-15°C to 50°C)
Storage temperature range
-15°C to 70°C (5°F to 158°F)
Humidity (operating and storage)
IEC 68-2-30/24 h 95% relative humidity +25°C to +40°C (+77°F to +104°F) (2 cycles)
Directives
EMC: 2014/30/EU
Vibration
2 g, 30 minutes confirmed

Physical data

Weight
1.6 kg (3.5 lb)
Cameras size, incl. lens (L × W × H)
201 × 150 × 101 mm (7.9 × 5.9 × 4.0 in)

Shipping information

Packaging, type
Hard case
Packaging, contents
  • GIS-320 camera head with lens
  • Lens cap
  • USB Flash drive 32 GB
  • HDMI cable
  • 10-pin standard cable
  • Power supply cable
  • 2x Software license Thermolab
  • My.Workswell card
  • Hard transport case
Packaging, weight
4.4 kg (9.7 lb)
Packaging, size
340 × 320 × 150 mm (13 × 12 × 6 in)
EAN-13
7332558027967
UPC-12
845188024222
Country of origin
Czech Republic

Box contents

  • GIS-320 camera with 14.5º or 24º lens
  • Lens cap
  • 32 GB USB flash drive
  • HDMI cable
  • Standard 10-pin cable
  • Power cable
  • 2 Thermolab software licenses
  • Rigid carrying case

Related products