FLIR EV45-T2 – EV Charging Adapter with Type 2 Plug and Type 1 Converter

794,00€ + VAT

Availability: 11-15 days

Ref: EV45-T2

Description

Test Adapter for FLIR EV45-T2 Chargers

The FLIR EV45-T2 test adapter is used to test AC electric vehicle charging stations with a Type 2 connector (IEC 62196-2)—the standard in Europe—in both residential and commercial settings. It includes a converter to Type 1 (SAE J1772).

It checks the protective conductor (PE) and the wiring, simulates the states of the control indicator (CP), indicates the maximum current the cable can handle (PP), and tests the residual current device (RCD/CCID) trip. Using a FLIR DM286 multimeter, it also measures the load voltage and frequency, and using the FLIR IM75-2, it allows for cable insulation testing.

Main features

  • PE Pre-test: Pass/Fault indication via touch sensor.
  • Simulation of CP states A, B, C, D, and E, and of CP and PE errors.
  • PP status indication: open, 13, 20, 32, and 63 A.
  • RCD/CCID Firing Test.
  • Phase designations L1, L2, and L3.
  • L1, L2, L3, PE, and N test terminals for a multimeter or insulation tester.
  • Approximate battery life of 100 hours with 4 AA alkaline batteries.

Common applications

  • Launch of Public and Private Charging Stations
  • Regular Maintenance of Charging Stations
  • Diagnosis and Repair of EVSE Equipment Malfunctions
  • Verification of the Electrical Safety of the Charging Point

Compatibility

For AC charging stations with a Type 2 connector (IEC 62196-2) and, with the included converter, a Type 1 connector (SAE J1772). Measurement outputs for the FLIR DM286 multimeter and the FLIR IM75-2 insulation tester.

REF: EV45-T2

Technical data

Test Functions

PE Pre-TestPass / Fault (>50 V AC/DC between the PE conductor and the touch sensor)
PP Status IndicatorOpen, 13 A, 20 A, 32 A, 63 A
CP State SimulationA (off), B (on), C (charging), D (charging with fan on), E (error)
Phase IndicationL1, L2, L3
CP Error Simulation (State E)Pass / Fault (CP signal shorted to PE)
PE Error SimulationPass / Fault (PE conductor interruption)
RCD/CCID Fire TestPass / Fault

Measurement outputs (for testing purposes only)

TerminalsL1, L2, L3, PE, N
Maximum Values250 V (single-phase) / 430 V (three-phase), 50/60 Hz, CAT II 300 V, max. 10 A
With the DM286 multimeterCP C/D Status: AC Voltage and Frequency
With the IM75-2 testerCP B Status: Cable Insulation Test

Feeding

Batteries4 AA alkaline batteries
AutonomyApprox. 100 hours

Connectors

Integrated connectorType 2 IEC 62196-2
Accessory AdapterIEC 62196-2 Type 2 to SAE J1772 Type 1

Environmental Conditions

How It Works-10 °C a 30 °C, <85 % HR; 30 °C a 40 °C, <75 % HR; 40 °C a 50 °C, <45 % HR
Storage-20 °C to 60 °C, 0 to 80% RH (without batteries)
Working Altitude2000 m
Level of pollution2

Physical data

Weight600 g
Dimensions (L x W x H)237 x 65 x 56 mm
Warranty3-Year Limited Warranty

Box contents

Box contents

EV45-T2 Test Adapter1 unit
Converter for Type 11 unit
Carrying case1 unit
Test cables1 set
AA batteries4 units
User Manual1 unit